Install and Wire Telephones and Other Equipment 
Page 5-41
Emergency Transfer Units and Associated Telephones 
5
13. Check the system for transfer operation as follows:
— Place the test switch (switch 12) in the ACTIVATED position.
— The power LED  should be OFF.
— Verify there is dial tone on all emergency transfer sets.
If all of the above conditions are not met, replace the panel.
The 808A connect to the MDF with a B25A cable. 
Figure 5-18
 shows the 
connections at the trunk/auxiliary field for a telephone used only for emergency 
transfer.
Figure 5-18.
Connections for Telephone Used for Emergency Transfer