Lucent Technologies Release 6 用户手册
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-87
Add Tie Trunks
5
Add Tie Trunks
Requirements
Each tie trunk connects to 1 port of a 4-port TN760 or to an assortment of
non-United States tie trunk circuit packs.
non-United States tie trunk circuit packs.
Installation
1. Determine the port assignment of the trunk from Trunk Group form.
2. Install a TN760 or a non-United States tie trunk circuit pack in the
assigned carrier slot (if an additional circuit pack is required).
3. For customer-owned (not leased) tie-trunk facilities (such as campus
environments), TN760 circuit packs provide signaling capabilities beyond
those specified by the industry-wide E & M standard. Use
those specified by the industry-wide E & M standard. Use
TN760 circuit pack, and administer the port.
4. Administer forms listed under “Tie Trunk Group” in
DEFINITY Enterprise
Communications Server Release 6 Administration and Feature
Description
Description
.
Port Number
3
A
02
01
Cabinet
Carrier
Slot
Circuit
(Port Network)
(or Single-Carrier
Cabinet)