Install and Connect Cabinets 
Page 1-26
Connect Remote Power Off Cable and External Alarm Cable 
1
!
CAUTION:
The auxiliary contacts inside the EPO switch assembly must close when the 
switch is pressed. This contact closure energizes the relay inside the power 
distribution unit, causing the connection to the battery holdover assembly to 
open.
Figure 1-10
 shows the cabling from the auxiliary contacts inside the EPO switch 
assembly and how they connect to the internal relay.
Figure 1-10.
Remote Power Off Cable Connections 
 
Part 2
1. Connect the RPO wires to the auxiliary contacts on the EPO switch. See 
Figure 1-10
.
NOTE:
The EPO switch and the auxiliary contacts for the RPO connection 
are customer-supplied.
Ground
Terminal
Bar
Shunt
RPO Cable
Power Distribution Unit
TB1
To Carriers
A to E
TB3
Auxiliary Contacts
in EPO Switch
2 6
Battery
Cabinet
0026_3 RBP 080196
Relay
(K1)