Pelco DRD14 用户手册

下载
页码 28
20
Pelco Manual C466M-E (6/99)
5.1.2  Extended Commands
Extended commands will always have B0 of Byte 2 set to one. The following num-
bers are in hexadecimal format:
Command
Byte 1
Byte 2
Byte 3
Byte 4
Set preset XX
00
03
00
01 to 20
Clear preset XX
00
05
00
01 to 20
Go to preset XX
00
07
00
01 to 20
80 FLIP preset
00
07
00
21
Set aux XX
00
09
00
01 to 08
Clear aux XX
00
0B
00
01 to 08
Remote Reset
00
0F
00
00
Program zone XX
starting point
00
11
00
01 to 08
Program zone XX
ending point
00
13
00
01 to 08
Write character YY
to screen position XX
00
15
0 to 27
YY
Clear screen
00
17
00
00
Zone Scan On
00
1B
00
00
Zone Scan Off
00
1D
00
00
Pattern Start Point
00
1F
00
00
Pattern Stop Point
00
21
00
00
Run Pattern
00
23
00
00
Lens Speed
00
25
00
00 to 03
5.2 AMERICAN DYNAMICS
AD2083 TYPE RS-422 CONTROL COMMAND
5.2.1  Protocol
1.
The following describes the protocol used to send commands to the receivers
via RS-422.
a.
The hardware interface is four-wire RS-422, where one pair is used to
issue commands to the receiver and one pair is used to receive responses
from the receiver.
b.
The protocol:  one start bit, eight bits data, and one stop bit at 2400 baud.
2.
The message format is 7 of these 10-bit words. Word one is the sync and is set
to 0xFF, word two is the receiver address, words three and four are referred to
as commands, words five and six as data, and word seven is the check sum.
Commands are divided into two categories. The first is referred to as PTZ (pan and
tilt and lens) commands, the second category is Extended commands.