Pelco C1303M-B (5/05) 用户手册

下载
页码 12
 
8
C1303M-B (5/05)
 
Maintenance
 
CAMERA MODULE REPLACEMENT
 
The ExSite camera module can be replaced only with a camera module with the same model number. If a different camera model is installed in 
an existing system, the system will not function and a message to contact the Pelco factory will appear on the screen.
To replace the camera module do the following:
a.
Loosen the set screw with a 1.5 mm Allen wrench.
b.
Use the supplied spanner wrench to loosen the back cap of the camera enclosure. Once the back is loose, use your hands to continue 
to loosen it until it can be removed.
 
Figure 6.  
 
Remove Back Cap of Camera Enclosure
 
 
Figure 7.  
 
Remove or Install Camera Module
 
DANGER:  
 
To reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from the power supply before opening.   
Keep assembly tightly closed when operating.
CAMERA
ENCLOSURE
BACK
SPANNER
WRENCH
SET SCREW
BUSHING
SET TAB IN
CENTER POSITION
CAMERA
MODULE
HANDLE
8-32 PHILLIPS FLAT
HEAD SCREW
ARM
STUD