Avaya R300 用户手册

下载
页码 112
DEFINITY Enterprise Communication Server Release 9
Getting Started with the Avaya R300 Remote Office Communicator  
Issue 1
November 2000
DEFINITY Administration for the Avaya R300 
61
Set up signaling group 
4
Setting up a trunk group
You can modify an existing trunk group or add a new one.
1. Type 
add trunk group <trunk group number or next>
.
Screen 16.
Trunk Group
2. On the Trunk Group screen, complete the following fields:
Group Type: Type ISDN.
Carrier Medium: Type IP.
Service Type: Type tie.
Codeset to Send Display: Type 0
The default is 6, and this should be changed to 0 to support interoperability 
with non-DEFINITY systems.
3. Go to the Group Member Assignments screen to associate the trunk group with the 
signaling group.
add trunk-group next
Page 1 of x
                                 TRUNK GROUP
Group Number: 6
Group Type: ISDN
CDR Reports: _
Group Name: Remote office 6
 COR: __
TN: ___
TAC: 6
 Direction: ________
Outgoing Display? _
Carrier Medium: ____
Dial Access? _
Busy Threshold: ___         Night Service: _____
Queue Length: ___ 
Service Type:tie
Auth Code? _
TestCall ITC: ____
Far End Test Line No:_
TestCall BCC: _
 TRUNK PARAMETERS
Codeset to Send Display:_ Codeset to Send National IEs:_ 
Maximum Message Size to Send:__
Charge Advice:____
Supplementary Service Protocol:_
Digital Handling (in/out):____
Trunk Hunt:________
Digital Loss Group:__
Calling Number - Delete: ____ Insert:_______Number Format:_____
Bit Rate: _____
Synchronization: _____ 
Duplex: ____
Disconnect Supervision - In? _
Out? _
Answer Supervision Timeout: _