Set up signaling group
4
Setting up a trunk group
You can modify an existing trunk group or add a new one.
1. Type
add trunk group <trunk group number or next>
.
Screen 16.
Trunk Group
2. On the Trunk Group screen, complete the following fields:
■
Group Type: Type ISDN.
■
Carrier Medium: Type IP.
■
Service Type: Type tie.
■
Codeset to Send Display: Type 0.
The default is 6, and this should be changed to 0 to support interoperability
with non-DEFINITY systems.
with non-DEFINITY systems.
3. Go to the Group Member Assignments screen to associate the trunk group with the
signaling group.
add trunk-group next
Page 1 of x
TRUNK GROUP
Group Number: 6
Group Type: ISDN
CDR Reports: _
Group Name: Remote office 6
COR: __
TN: ___
TAC: 6
Direction: ________
Outgoing Display? _
Carrier Medium: ____
Dial Access? _
Busy Threshold: ___ Night Service: _____
Queue Length: ___
Service Type:tie
Service Type:tie
Auth Code? _
TestCall ITC: ____
Far End Test Line No:_
TestCall BCC: _
TRUNK PARAMETERS
TRUNK PARAMETERS
Codeset to Send Display:_ Codeset to Send National IEs:_
Maximum Message Size to Send:__
Charge Advice:____
Supplementary Service Protocol:_
Digital Handling (in/out):____
Trunk Hunt:________
Digital Loss Group:__
Calling Number - Delete: ____ Insert:_______Number Format:_____
Bit Rate: _____
Synchronization: _____
Duplex: ____
Disconnect Supervision - In? _
Out? _
Answer Supervision Timeout: _