Tascam MD-CD1MKIII 用户手册

下载
页码 56
 
TASCAM MD-CD1MKIII
  
49
Data communication settings
By connecting a PC through its RS-232C terminal to 
the MD-CD1MKIII through its CONTROL I/O (RS-232C) 
terminal, the two units can be linked for data exchange. 
Use the following options on the SERIAL sub-menu of the 
CD menu to perform their respective settings.
BAUD RATE
Sets the communication speed of the keyboard.
4800/9600/19200/38400 bps can be selected.
Default: 9,600
LENGTH
Communication word length can be set to either 7 or 8 
bits.
Default: 8 bits
PARITY
Communication parity can be set to NON, EVEN or ODD.
Default: NON
STOP BIT
The data stop bit can be set to either 1 or 2.
Default: 1
Viewing service data
You can view service data via the following items in the 
SYSTEM submenu of the CD menu.
CD P_TIME
The total CD playback time is shown.
MD P_TIME
The total MD playback time is shown.
MD R_TIME
The total MD recording time is shown.
Initializing all data
You can reset all data to initial default settings.
1  Make sure that no disc is loaded in the MD or 
CD player. Select the 
F_PRESET
? option on the 
SYSTEM sub-menu of the CD menu.
The display indicates 
Sure?
.
2  Press the MULTI JOG dial (or YES button) on the 
unit or the ENT/YES button on the remote control.
All data will be initialized to the default settings.
CAUTION
Do not turn off the power to the unit until the 
• 
Complete
 indicator on the display disappears.
If the settings are initialized, all the programs retained 
• 
for each disc will be erased.
14 – Data settings/Service Data