NEC RS-232C 用户手册

下载
页码 72
 
(5/72) 
III. Communication specification 
3. Communication Parameter 
3.1 RS-232C Remote control 
(1) Communication system 
Asynchronous 
(2) Interface   
 
RS-232C 
(3) Baud rate   
 
9600bps 
(4) Data length 
 
8bits 
(5) Parity 
 
 
None 
(6) Stop bit 
 
 
1 bit 
(7) Communication code   
ASCII 
 
3.2 LAN control 
(1) Communication system 
TCP/IP (Internet protocol suite)  
(2) Interface   
 
Ethernet (CSMA/CD) 
(3) Communication layer  
Transport layer (TCP)  
 
 
 
 
* Using the payload of TCP segment. 
(4) IP address  
 
(Default) 192.168.0.10 
 
 
 
 
* If you need to change, 
 
 
 
 
Please refer 
“Network settings” on User’s manual. 
(5) Port No. 
 
 
7142 (Fixed) 
 
(Note) 
The monitor will disconnect the connection if no packet data is received for 15 minutes. 
And the controller (PC) has to re-connect to control the monitor again, after 15 minutes or more. 
 
3.3 Communication timing 
The controller should wait for a packet interval before next command is sent. 
The packet interval needs to be longer than 600msec for the LCD monitor.