NEC RS-232C 用户手册

下载
页码 72
 
(68/72) 
 
13. Security Lock 
13.1 Security Lock Control 
 
This command sets the condition of security lock function to "LOCK" or "UNLOCK". 
 
If security pass codes 1st to 4th are matched with monitor resisted pass codes, then this 
command is executed, and reply no error status and a new condition. 
If codes aren't matched with them then setting isn't changed, and reply error status and 
a current condition. 
If the monitor receives this command while waiting for Pass codes inputs, then it only 
checks Pass cords (and releases image muting if Pass codes are OK) and doesn't apply "EN" 
parameter. 
 
1) The controller requests the monitor to set the condition of security lock. 
Header 
Message 
Check 
code 
Delimiter 
SOH-'0'-MonitorID-'0'-'A'-'1'-'0'  STX-'C'-'2'-'1'-'D'-EN-P1-P2-P3-P4-ETX 
BCC 
CR 
 
Header 
SOH (01h): Start Of Header 
'0' (30h): Reserved 
Monitor ID: Specify the Monitor ID of which you want to change a setting. 
Ex.) If Monitor ID is '1', specify 'A'. 
'0' (30h): Message sender is the controller. 
'A' (41h): Message type is "Command". 
'1'-'0'(31h, 30h): Message length 
 
Message 
STX (02h): Start of Message 
'C'-'2'-'1'-'D'  (43h, 32h, 31h, 44h): Security Lock Control command 
EN-P1-P2-P3-P4: Lock condition control data 
EN: Enable /Disable 
'0'-'0'(30h, 30h): Disable 
'0'-'1'(30h, 31h): Enable 
 
P1: Security Pass code 1st 
'0'-'0'(30h, 30h): "0" 
   | 
'0'-'9'(30h, 39h): "9" 
 
P2: Security Pass code 2nd 
'0'-'0'(30h, 30h): "0" 
   | 
'0'-'9'(30h, 39h): "9" 
 
P3: Security Pass code 3rd 
'0'-'0'(30h, 30h): "0" 
   | 
'0'-'9'(30h, 39h): "9" 
 
P4: Security Pass code 4th 
'0'-'0'(30h, 30h): "0" 
   | 
'0'-'9'(30h, 39h): "9" 
 
ETX (03h): End of Message 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation. 
 
Delimiter 
CR (0Dh): End of packet 
 
2) The monitor replies the result to the controller.