Cooling system
To keep the working temperature as low as possible the 
machine is equipped with a cooling system.
The cooling system consists of:
1
Air intake on the starter.
2
Air guide plate.
3
Fins on the flywheel.
4
Cooling fins on the cylinder.
5
Cylinder cover (directs cold air over the cylinder).
Clean the cooling system with a brush once a week, more 
often in demanding conditions. A dirty or blocked cooling 
system results in the machine overheating which causes 
damage to the piston and cylinder.
Note! The cooling system on a chain saw with catalytic 
converter must be cleaned daily. This is particularly 
important on chain saws with catalytic converters, 
because the higher exhaust temperature requires efficient 
cooling of the engine and the catalytic converter unit.
”Air Injection” centrifugal 
cleaning
Centrifugal cleaning means the following: All air to the 
carburetor passes through the starter. Dirt and dust is 
pushed out by the cooling fan.
IMPORTANT! In order to maintain operation of the 
centrifugal cleaning system it must be regularly 
maintained. Clean the air intake to the starter, the fins on 
the flywheel, the space around the flywheel, inlet pipe and 
carburetor compartment.
Winter use
Running problems can occur when using the machine in 
the cold and snowy conditions caused by:
Too low engine temperature.
Icing of the air filter and carburetor.
Special measures are therefore often required:
Preheat the intake air to the carburetor by using the 
heat from the cylinder.
Partly mask the air inlet on the starter to increase the 
working temperature of the engine.
Fitting the winterising kit
Cut out a hole using a knife as shown.
Fit the winter cover in the cylinder cover.
Temperature 0
°°°°C (32°°°°F) or colder:
Move the cover from position A to position B so that 
preheated air from the cylinder can pass into the 
carburettor compartment and prevent, e.g. the air filter 
icing up again. When fitting the winter cover in position B 
the centrifugal cleaning nozzle is blocked. This measure 
requires the air filter to be cleaned more regularly.
THIS SIDE
VISIBLE
537 21 05 XX