Husqvarna TS 500 M 用户手册

下载
页码 32
• Loosen  the  4  fixing  screws  and  remove
the side cover.
• Using  the  19  mm  key,  loosen  the
tensioner screws.
• Using a lever, tighten the belt. If the belt is
not  tight  enough,  bear  on  the  motor,  then
again on the tensioner.
• Each saw is fitted with a pump in order to
eliminate dust and overheating.
• The  blade  is  cooled  automatically  as  the
machine starts.
13
Blade cooling
12
Changing the belt
• The  machine  is  set  before  leaving  the
factory and no adjustment is necessary.
• However,  after  shocks,  loosening  of  nuts
and  bolts,  or  sharp  movements  when
tilting  the  head,  if  necessary  adjust  the
stop screws (J) and check the squareness
(for straight cuts).
14
Adjustments
• Retighten the nuts and bolts periodically.
• In  the  event  of  a  long  period  of  use  pay
special  attention  to  the  maintenance  and
protection of the disc.
• Make sure that sufficient water is sprayed
onto the disc.
• Tighten the disc correctly.
• Make  sure  that  the  contact  faces  of  the
disc,  the  flanges  and  the  spindle  are
clean.
15
Important advice
12
The  manufacturer  declines  all
responsibility  for  loss  or  damage
resulting  from  misuse  or  any
modification,  alteration  or
powering  that  does  not  conform
to  the  manufacturer's  original
specifications.
At  the  work  station,  the  sound
pressure level may exceed 85 db
(A)
In this case individual protection
measures must be taken.
16
Repairs
Contact  your  supplier  who  is
entirely  at  your  service  to  carry
out repairs in the shortest time at
the best possible price.
S
A
V
17
Spare parts
For rapid delivery of spares and in order to
avoid  any  wasted  time,  it  is  necessary  to
remind  your  supplier  of  the  details  shown
on the instruction plate on the machine with
each order, as well as the reference of the
part to be replaced.
The instructions for use and spare parts
found in this document are for information
only and are not binding.
As part of our product quality improvement
policy, we reserve the right to make any
and all technical modifications without prior
notice.
In  the  event  of  deterioration  and
scrapping  of  the  machine,  the
following 
items 
must 
be
disposed  of  in  accordance  with
the 
requirements 
of 
the
legislation in force.
18
Scrapping
• Main materials :
-
Motor : Aluminium (AL), Steel (AC),
Motor :
Copper (CU), Polyamide (PA)
-
Machine : Steel sheet (AC)
-
Machine 
Cast iron (FT)
FAULT FINDING
In  the  event  of  faulty  operation  refer  to  the
tables below to find a solution.
• The machine does not work
CAUSES
Not plugged in
properly or cable
damaged
No mains voltage
Switch defective,
motor cable
damaged
Motor faulty (no
power, unpleasant
smell)
- Make sure that
the supply is
correctly plugged
in (plug,
extension lead,
etc)
- Check the supply
cable
- Test or have
tested by an
electrician
(circuit breaker,
plug, etc)
- Have tested by
an electrician or
contact the
service
department
- Contact the
service
department to
have the motor
replaced
REMEDIES
• Difficult starting
CAUSES
Single phase motor
starting condenser
Three-phase
supply not correct
(on 2 phases,
motor cable faulty)
- Replace the
condenser
- Have it checked
by an electrician
or contact the
service
department
REMEDIES
• The pump does not start
CAUSES
The mains lead is
not correctly
connected or is
damaged
No voltage in pump
circuit or mains
supply circuit
- Check the mains
lead
- Check the pump
circuit and mains
supply circuit
REMEDIES
• The pump does not pump water
CAUSES
An air bubble may
have formed inside
the pump body
The turbine is
jammed
- Holding the pump
of the outlet pipe
remove it from
the water and
reimmerse it
- Unscrew the filter
and, using a
small
screwdriver,
remove all dirt
from the
operating area of
the turbine.
REMEDIES
English
See exploded view
00000000     (0)
Item number