Husqvarna 230 ACX 用户手册

下载
页码 82
52 - English
6. MENU FUNCTIONS
Up to five remote areas can be activated: Area 1, 
Area 2, Area 3, Area 4 and Area 5
 (only three 
areas on 220 AC). Three values need to be 
stated to activate an area: 
• Direction
Specify to the right, left, guide 1 or guide 2 
depending on which direction the area lies from 
the charging station. The direction is set 
looking from the charging station in the 
approach direction of the mower.
When a guide wire is installed the direction can 
be specified as the guide wire. The mower will 
now follow the selected guide wire instead of 
the boundary wire, (only guide 1 is available on 
220 AC).
• Distance
Specify the number of metres along the 
boundary wire or guide wire from the charging 
station to the place in the remote area where the 
mower shall start mowing.
Tip!
 Use the Test OUT (3-2-5) function (see 
page 55) to find out how far it is to the remote 
area. The distance, stated in metres, will appear 
on the mower display.
• Proportion
Specify a value for how often of the occasions 
Automower leaves the charging station it should 
follow the loop out to the remote area.
For example the value 20 % means that in 20 % 
of the occasions Automower leaves the charging 
station, it does it in the direction to the remote 
area. In the remaining 80 % of the occasions the 
mower leaves the charging station according to 
the setting made for its function Exit angles 
(3-1)
.
If a value of 20 % is specified for Area 1 and 
10 % for Area 2, the remaining 70 % is allocated 
to the selection under Exit angles (3-1).
3-2-1
Area 1
Area 2
Area 3
Area 4
Area 5
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT
Direction
Distance
Proportion
Area 1
Area 2
Area 3
Area 4
Area 5
Right
Left
Guide 1
Guide 2
Direction
Distance
Proportion