Husqvarna 230 ACX 用户手册

下载
页码 82
74 - English
9. TROUBLE SHOOTING
Outside working area
If this occurs in isolated areas it may 
be due to interference from metallic 
objects (perimeter fence, 
reinforcement bar) or buried cables in 
the vicinity.
Try moving the boundary wire.
The working area slopes too much.
Check that the boundary wire has 
been routed correctly.
The boundary wire has been routed 
the wrong way around an island.
Check that the boundary wire has 
been routed in accordance with the 
installation instructions.
The boundary wire is too close to the 
edge of the working area.
Check that the boundary wire has 
been routed correctly.
Low battery voltage
Automower cannot find the charging 
station.
 Change the search settings 
according to the Follow loop in (3-2-2) 
on page 53.
Change the position of the charging 
station.
The battery is spent.
Expected life is 1 - 4 years. Contact 
your dealer to replace the battery.
Wrong PIN code
Wrong PIN code has been entered. 
Three attempts are permitted, the 
keypad is then blocked for five 
minutes.
Enter the correct PIN code.
No drive
Automower has got caught in 
something.
Free the mower and rectify the 
reason for the lack of drive. If it is due 
to wet grass, wait until the lawn has 
dried before using the mower.
No contact in charging 
station
Automower makes poor contact with 
the contact strips in the charging 
station.
Check that Automower has docked 
correctly in the charging station.
Charging station 
blocked
The contact between the charging 
strips and contact strips may be poor 
and Automower has made a number 
of charging attempts.
Place Automower in the charging 
station and check that the charging 
strips and contact strips make good 
contact.
An object is obstructing Automower.
Remove the object.
Stuck in charging 
station
An object is preventing Automower 
from reversing out of the charging 
station.
Remove the object.
Upside down
Automower leans too much or has 
turned over.
Turn the mower the right way up.
Needs manual 
charging
Automower is set in MAN operating 
mode.
This behaviour is normal; no action 
required.
Fault message
Cause
Action