7. GARDEN EXAMPLE
Area: 5000 m
2
. No guide wire is necessary.
Timer: Operating time of 24 hours per day.
Exit angles: 90° - 270°.
Search method: Irregular and Follow 
boundary wire in.
Delay: Guide 1 4 minutes, Guide 2 4 minutes 
and boundary wire 11 minutes.
Corridor width: Boundary wire 20
Area: 4500 m
2
. A number of islands and a 
steep slope along the boundary wire. Guide 
wire recommended.
Timer: Operating time of 24 hours per day.
Exit angles: 90°-270°.
Search method: Irregular and Follow guide 
wire in.
Delay: Guide 1 4 minutes, Guide 2 4 minutes 
and boundary wire 99 minutes.
 
Automower
®
 
is never permitted to follow the boundary 
wire.
Corridor width: Guide 1 20, Guide 2 20.
Area: 1600 m
2
. L-shaped garden with the 
charging station placed in the large open 
area. No guide wire is necessary.
Timer: Operating time of 8 hours per day.
Exit angles: 90°
 
- 270°.
Search method: Irregular and Follow 
boundary wire in.
Delay: Guide 1 4 minutes, Guide 2 4 minutes 
and boundary wire 11 minutes.
Corridor width: Boundary wire 20
Proposals for installation and settings