Husqvarna 2003-06 用户手册

下载
页码 50
English-
34
MENU FUNCTIONS
Drive past wire (3-2)
The front of the Auto Mower always passes the bound-
ary wire by a specific distance before the mower turns. 
The default distance is 27 cm, but this can be changed 
if required.
To adjust the distance: Move the cursor to ”Drive 
past wire” and press YES. Now state the number of 
centimetres you want the Auto Mower to pass the 
boundary wire.
Garden shape (3-3)
The Auto Mower can be set according to three garden 
shapes: open, complex 1 and complex 2. See exam-
ples of garden shapes on page 16. Many gardens can 
be characterised as open, which is also the default set-
ting on the Auto Mower. 
Open (3-3-1)
Select ”Open” if your garden has an open lawn, few 
obstacles and no passages.
Complex 1 (3-3-2)
Select ”Complex 1” if your garden has an average 
number of obstacles and/or passages.
Complex 2 (3-3-3)
Select ”Complex 2” if you garden has a large lawn 
and many obstacles and/or passages.
Check loop (3-4)
This function allows you to check the mower’s signal 
reception from the boundary wire, and to determine 
exactly where in the lawn the boundary wire is routed.
The sensor used for this function sits concealed 
directly under the catch button for the cutting height 
adjustment cover. The sensor detects the position of 
the Auto Mower in relation to the loop. ”Inside”, ”Out-
side” or ”No loop signal” are shown on the display. If 
the mower is inside the loop, ”Inside” is shown, etc. If 
the mower is set with sound on, a constant beep is also 
heard when the mower is outside and a pulsating beep 
when it cannot detect a signal. If the mower is inside 
the loop no beep is heard.
To:
Check the signal reception: Move the cursor to 
”Check loop” and press YES.
Find wire: Move the Auto Mower over the outer 
edge of the working area and select ”Check loop”. 
Repeat until you find the boundary between ”Inside” 
and ”Outside”. You now know where the wire is.
Charge exit settings
Drive past wire
Garden shape
Check loop
3-2
_ _
Charge exit settings
Drive past wire
Garden shape
Check loop
3-3
Open
Complex 1
Complex 2
3-3-
Charge exit settings
Drive past wire
Garden shape
Check loop
3-4