3. INSTALLATION
It is possible to let the low voltage cable cross the 
working area. The low voltage cable must be stapled 
down or buried, and the cutting height should be such 
that the blades on the blade disc can never come in 
contact with the low voltage cable. 
Make sure the low voltage cable is laid along the 
ground and secured with pegs 75 cm apart. The 
cable must lie close to the ground so as not to be cut 
before the grass roots have grown over it.
The transformer must be placed where it is well 
ventilated and is not exposed to direct sunlight. The 
transformer must be placed under a roof. 
It is recommended to use an earth fault-breaker when 
connecting the transformer to the wall socket.
The transformer must be mounted on a vertical 
surface, such as a wall or a fence. Screw the 
transformer in place using the two mounting eyelets. 
No screws are supplied. Select screws suitable for 
the material in question. 
Do not, under any circumstances, mount the 
transformer at a height where there is a risk it can be 
submerged in water (at least 30 cm from the ground). 
It is not permitted to place the transformer on the 
ground. 
IMPORTANT INFORMATION
The low voltage cable must not under any 
circumstances be shortened or extended.
IMPORTANT INFORMATION
Place the low voltage cable so that the blades 
on the blade disc can never come in contact 
with it. 
IMPORTANT INFORMATION
Use the plug to disconnect the charging 
station, for instance before cleaning or 
repairing the loop wire.
3018-085
min 30cm/12”
3018-094