MAINTENANCE
V-BELTS
Check V-belts for deterioration and wear after 100 hours 
of operation and replace if necessary. The belts are not 
ad just able. Re place belts if they begin to slip from wear.
TRANSAXLE COOLING
The transmission fan and cooling fins should be kept clean 
to assure proper cooling.
Do not attempt to clean fan or transmission while engine 
is running or while the transmission is hot. To prevent pos-
 si ble damage to seals, do not use high pressure water or 
steam to clean transaxle.
• 
Inspect cooling fan to be sure fan blades are intact and 
clean.
•  Inspect cooling fins for dirt, grass clippings and other 
materials.  To prevent damage to seals, do not use 
compressed air or high pressure sprayer to clean cool-
ing fins.
TRANSAXLE PUMP FLUID 
The transaxle was sealed at the factory and fluid main te -
nance is not required for the life of the transaxle.  Should 
the transaxle ever leak or require servicing, contact your 
near est au tho rized ser vice center/department.
TO CHANGE ENGINE OIL (See Figs. 14 and 15) 
Determine temperature range expected before oil change.  
All oil must meet API service classification SG-SL.
•  Be sure tractor is on level surface.
•  Oil will drain more freely when warm.
•  Catch oil in a suitable container.
• 
Remove oil fill cap/dipstick.  Be careful not to allow dirt 
to enter the engine when changing oil.
02
463
CLOSED AND 
LOCKED 
POSITION
YEL LOW 
CAP
DRAIN 
TUBE
OIL DRAIN VALVE
FIG. 15
FIG. 14
ENGINE
LUBRICATION
Only use high quality detergent oil rated with API service 
classification SG-SL.  Select the oil’s SAE viscosity grade 
according to your expected operating temperature.
NOTE:  Although multi-viscosity oils (5W30, 10W30 etc.) 
improve starting in cold weather, they will result in increased 
oil consumption when used above 32°F.  Check your engine 
oil level more frequently to avoid possible engine damage 
from running low on oil.
Change the oil after every 50 hours of operation or at least 
once a year if the tractor is not used for 50 hours in one 
year.
Check the crankcase oil level before starting the engine 
and after each eight (8) hours of operation.  Tighten oil fill 
cap/dipstick securely each time you check the oil level.    
TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE
SAE VISCOSITY GRADES
-20
0
30
40
80
100
-30
-20
0
20
30
40
F
C
32
-10
10
60
5W-30
SAE 30
oil_visc_chart1_e
• 
Remove yellow cap from end of drain valve and install 
the drain tube onto the fitting. 
CLEAN AIR SCREEN 
Air screen must be kept free of dirt and chaff to prevent 
engine dam age from overheating.  Clean with a wire brush 
or compressed air to re move dirt and stubborn dried gum 
fibers.
AIR FILTER 
Your engine will not run properly using a dirty air filter. 
Service air cleaner more often under dusty conditions. See 
Engine Manual.
ENGINE OIL FILTER
Replace the engine oil filter every season or every other 
oil change if the tractor is used more than 100 hours in 
one year.
MUFFLER   
Inspect and replace corroded muffler and spark arrester 
(if equipped) as it could create a fire hazard and/or dam-
age.
SPARK PLUGS 
Replace spark plugs at the beginning of each mowing 
season or after every 100 hours of operation, whichever 
occurs first.  Spark plug type and gap setting are shown in 
“PROD UCT SPECIFICATIONS” section of this manual.
•  Unlock drain valve by pushing inward and turning 
coun ter clock wise. 
•  To open, pull out on the drain valve. 
•  After oil has drained completely, close and lock the 
drain valve by pushing inward and turning clockwise 
until the pin is in the locked position as shown. 
• 
Remove the drain tube and replace the cap onto to the 
bottom fitting of the drain valve. 
•  Refill engine with oil through oil fill dipstick tube.  Pour 
slowly.  Do not overfill.  For approximate capacity see 
“PRODUCT SPECIFICATIONS” section of this man-
 u al.
•  Use gauge on oil fill cap/dipstick for checking level.  
Insert dipstick into the tube and rest the oil fill cap on 
the tube.  Do not thread the cap onto the tube when 
taking reading.    Keep oil at “FULL” line on dipstick.  
Tighten cap onto the tube securely when finished.