3. Installation
The charging station must be positioned with a great 
deal of free area in front of it (at least 3 metres). It 
should also be positioned centrally in the working 
area so that Automower can easily find the charging 
station and quickly reach all parts of the working area.
It is a good idea to place the charging station in the 
shadow. The battery is spared if it is charged in the 
lowest possible ambient temperature.
The charging station must be positioned on relatively 
level ground. The height difference must not differ 
more than 5 cm between the front and rear of the 
charging station.
The charging station must not be positioned so that 
its plate bends.
Consider the distance to a wall socket when choosing 
the position. The charging station should be 
connected to a 230V wall socket via the low voltage 
cable and transformer. 
The supplied low voltage cable is 20 metres long.
Tip!
 It is possible to let the low voltage cable cross 
the working area. It must then be either stapled down 
or buried. In some cases there is a better positioning 
option for the charging station than close to a house 
wall or by the closest wall socket.
The transformer must be placed where it is well 
ventilated and is not exposed to direct sunlight. It is 
also beneficial if the transformer can be placed under a 
roof.
It is recommended to use an earth fault-breaker when 
connecting the transformer to the wall socket.
IMPORTANT INFORMATION
The low voltage cable must not be extended.
3012-510
3012-554
3012-532
3012-220 
3012-223