Maintenance
Restoring from service position
1
Grip the front edge of the unit and loosen the lock, fold 
down and slide in the unit.
2
Replace the cutting height stay and the belt.
3
Tension the belt with the belt adjuster.
4
Fit the front cover.
Checking the blades
To achieve the best mowing results it is important that the 
blades are undamaged and well-sharpened.
Check that the blades’ attachment screws are tight.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles 
that result in a breakdown. Let the servicing dealer judge 
whether the blade can be repaired/ground or must be 
discarded.
Removing the BioClip plug
To change a Combi unit from BioClip function to cutting unit 
with rear ejection, remove the BioClip plug located under the 
unit with three screws.
CombiClip 103, CombiClip 112
1
Put the unit in the service position, see Placing in the 
service position.
2
Remove the three screws holding the BioClip plug, and 
remove the plug.
3
Tip: Fit three full-thread screws M8x15 mm in the screw 
holes to protect the threads.
4
Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
CombiClip 94 
1
Put the unit in the service position, see Service position 
for the cutting unit.
2
Loosen the knob holding the BioClip-plug and remove the 
plug.
3
Replace the unit in normal position.
IMPORTANT INFORMATION Replacing or sharpening the 
blades should be conducted by an authorised service 