2010 Portable Spa
LTR20101000, Rev. C
Operating 
Your Spa
www.calspas.com
16
The “FILTER 1” indicator icon will light when filter 
1 is running.
The second filter cycle is automatically activated 
• 
at 8:00 PM and operates the pump until 10:00 PM. 
The “FILTER 2” indicator icon will light when filter 
2 is running.
The  pump  and  the  ozone  generator  will  run  during 
filtration. At the start of each filter cycle, the blower 
will run on highest speed for 30 seconds to clean out 
the  air  channels.  The  lowest  speed  of  pump  2  and 
pump 3 will run for five minutes. In the event of power 
loss  or  shut  down,  the  time  of  day  will  need  to  be 
reset for filter cycles to run according to your desired 
programming.
Clean up Cycle
When the pump or blower is turned on by a button 
press,  a  clean-up  cycle  begins  30  minutes  after  the 
pump or blower is turned off or times out. The pump 
and the ozone generator will run for one hour.
Ozone
This is an optional feature. On most systems, the ozone 
generator (if installed) runs during filter cycles (except 
when pump 1 is operating at high speed on a non-circ 
ulating system) and during clean-up cycles. On some 
systems,  the  ozone  generator  operates  whenever 
the pump runs. If your system is configured with the 
optional  ozone  disable  feature,  the  ozone  generator 
will turn off for one hour any time a function button 
(“JETS 1”, “JETS 2”, “OPTION” etc.) is pressed.
Freeze Protection
If  the  temperature  sensors  detect  a  drop  to  44°F 
within  the  heater,  the  pump  automatically  activates 
to  provide  freeze  protection.  The  equipment  stays 
on  until  four  minutes  after  the  sensors  detect  that 
the  spa  temperature  has  risen  to  45°F  or  higher.  In 
colder  climates,  an  optional  additional  freeze  sensor 
may be added to protect against freeze conditions that 
may not be sensed by the standard sensors. Auxiliary 
freeze sensor protection acts similarly except with the 
temperature thresholds determined by the switch and 
without a four-minute delay in turnoff.