Framing and Support
A technical specifications manual has been included with your bathtub. The Technical Specifications Manual will  
contain pertinent information regarding your Jacuzzi Luxury Bath product. Locate the Technical Specifications Manual 
at this time. 
Frame out the space where the bathtub is to be located. The 
following should be taken into consideration when preparing 
the area:
• 
Dimensions provided on rough-in diagrams are 
   nominal. Measure your actual unit upon receipt and 
  build according to the actual dimensions.
• 
The floor structure beneath the bathtub must be able 
  to support the total weight of the bathtub, water and  
  bather.
• 
The unit must be supported from the bottom of the  
  bathtub and not from the bathtub rim. For drop-in  
  installations, take into account the thickness of the  
  surround material and finishing material (marble, tile, 
  etc.).
• 
Ensure the rim will rest on a level surface.
• 
Per code, access must be provided to the motor/pump 
  for your specific model. Primary and secondary service  
  access locations are shown in the rough-in diagrams  
  contained in the Technical Specifications Manual.  
 
  It is the responsibility of the installer, building 
contractor, or owner to provide access for service. 
Jacuzzi is not responsible for any costs relating to 
obtaining access for repair. The owner shall bear such 
costs and, if appropriate, must seek recovery from the 
installer.
• 
Provide adequate ventilation for cooling and supply  
  sufficient air for the motor/pump. Do not insulate  
  around the equipment. 
• 
Your bathtub may have motor/pump parts that extend  
  beyond the rim of the bathtub. Refer to the rough-in  
  diagrams included in the warranty pack and  
  construction framing to correctly accommodate.
Common Access Locations
= Primary access
= Acceptable alternative if access 
A
 is not possible
= Secondary access for equipment (optional)
Left hand unit access is on the opposite side (mirror).
A
B
C
Figure 4
Figure 5
Subfloor
Prepare the subfloor for the drain and ensure that the area is level. 
1
  The drain/overflow of the bathtub extends below the bottom of the bathtub. Identify the drawing in the Technical 
Specifications Manual that corresponds with your bathtub. 
2
  Make appropriate cuts to the subfloor to accommodate the drain.
3
  Jacuzzi’s Tru-Level™ base is a standard feature on all bathtubs. If the subfloor is level and a continuous surface, 
no other preparation is necessary. Proceed to the “Installation” section. 
4
  If the subfloor is not level, you must level the entire surface prior to installing the bathtub. The materials used  
will insure that the bathtub is supported from the bottom. These materials include: leveling compound, mortar, 
plaster or minimal expansion structural foam (having a density of a minimum 5lbs/cubic foot). The bathtub must 
remain level in order for it to drain properly and must make contact with the leveling material. Both sides of a joint 
or splice of subfloor should be level to each other.
    12˝ 
(304mm)
    18˝ 
(457mm)
    18˝ 
(457mm)
Motor
Secondary
Access
Primary
Access   
    20˝ 
(508mm)
    24˝ 
(609mm)
     36˝ 
(914mm)
B
A
C
Motor