Multiquip DCA400SSI 用户手册

下载
页码 98
DCA400SSI GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 41
MAINTENANCE
The purpose of these receptacles is to provide power via 
commercial power to the jacket water heater and internal 
battery charger. 
These receptacles will ONLY function when commercial 
power has been supplied to them (Figure 59). To apply 
commercial power to these receptacles, a power cord of 
adequate size will be required (See Table 6).
When using the generator in hot climates there is no reason 
to apply power to jacket water heater. However, if the 
generator will be used in cold climates it is always a good 
idea to apply power to the jacket water heater at all times. 
To apply power to the jacket water heater simply apply 
power to the jacket water heater receptacle via commercial 
power using an power cord of adequate size. 
Battery Charger and Jacket Water 
Figure 59. 
Heater Power Connections
If the generator will be used daily, the battery should 
normally not require charging. If the generator will be idle 
(not used) for long periods of time, apply power to the 
battery charger receptacle via commercial power using a 
power cord of adequate size.
 NOTICE
To ensure adequate starting capability, always have 
power applied to the generator's internal battery 
charger.