PAGE 24 — DA7000 SERIES GENERATORS• OPERATION AND PARTS MANUAL — REV. #5 (01/20/11) 
INSPECTION/SETUP
Before Starting
1.  Read safety instructions at the beginning of manual.
2.  Clean the generator, removing dirt and dust, particularly 
the engine cooling air inlet.
3.  Check the air fi lter for dirt and dust. If air fi lter is dirty, 
replace air fi lter with a new one as required.
4.  Check fastening nuts and bolts for tightness
Engine Oil Check
1.  To check the engine oil level, place the generator on 
secure level ground with the engine stopped.
2.  Remove the dipstick from its holder (Figure 7) and wipe 
clean.
Figure 7.  Engine Oil Dipstick Removal
3.  Re-Insert dipstick (Figure 8), then remove dipstick from 
its holder. Check the oil level shown on the dipstick.
Figure 8.  Engine Oil Dipstick
4.  If the oil level is low, remove the oil fi ller cap (Figure 9) 
and fi ll to a safe operating level (max) as indicated by 
the dipstick. Fill with recommended type oil as listed in 
Table 5. Maximum oil capacity is 2.64 quarts (2.5 liters).
Figure 9.  Engine Oil Filler Port
Table 5.  Oil Type
Temperature
Oil Type 
Above 77° F  (25° C)
SAE 30    or  SAE10W-30
                     SAE 15W-40                        
32°~ 77° F
(0° ~ 25° C)
SAE 20    or  SAE10W-30
                     SAE 15W-40
Below 32° F  (0° C)
SAE 10    or  SAE10W-30
                     SAE 15W-40