Mitsubishi 5P-H5F 用户手册

下载
页码 4
MITSUBISHI MGS SERIES 
DIESEL GENERATOR SET 
50Hz/1500 rpm/380V 
 
 
 
 
 
POWER RATING (0.8 P.F.) 
MODEL CODE 
STAND-BY 
690 kVA 
5S-H5F 
PRIME 
625 kVA 
5P-H5F 
 
 
 
 
 
 
 
 
 
MGS0500B with typical options 
Voltage Variation 
■  Standard Voltage 
3Phase 4 Wires 
 
380V 
■  Voltages Available 
3Phase 4 Wires   
 
380, 400, 415, 440, 190, 200, 208 and 220V 
Note: 
Outputs for optional voltages may differ from standard output mentioned above. 
 
 
CONDITIONS & DEFINITIONS 
Stand-by: Code: S 
Applicable for supplying emergency power at varying load in the event of the normal utility power interruption. 
Fuel stop power in accordance with ISO15550, ISO3046/1, JISB8002-1, DIN6271 and BS5514. 
Overload: not allowed 
 
Prime: Code: P 
Applicable for supplying emergency power at varying load in the event of normal utility power interruption. + 10% overload 
in accordance  with ISO3046/1. Overload power in accordance with  ISO15550, ISO3046/1, JIS8002-1, DIN6271 and 
BS5514. 
 
Conditions: 
Engine ratings are based on SAE J1349 standard conditions and also apply at ISO3046/1, DIN6271 & BS5514 standard 
conditions. 
Fuel rates: based on ASTM D975, BS2869 and on fuel oil of 35° API (16°C or 60° F) gravity having a LHV of 42,780 kJ/kg 
(18,390 Btu/lb.) when used at 29°C (85° F) and weighing 838.9 g/liter (7.001lbs./U.S. gal.). 
 
Note:  * For conditions of prime power (P.R.P.) and additional rating requirements, please consult your nearest Mitsubishi 
  MGS dealer. 
 
 
DIMENSION (Reference Data) 
 
Overall dimensions 
L :  Length 
mm 
3600 
 
W :  Width 
mm 
1710 
 
H :  Height 
mm 
1935 
Total Weight (Dry) 
 
kg 
5000 
Total Weight (Wet) 
 
kg 
5300 
 
 
 
M
M
G
G
S
S
0
0
5
5
0
0
0
0
B
B