Siemens 580 用户手册

下载
页码 35
 
- 32 -
Vibration Analysis Sheet 
 
Pick-Up 
Filter-Out Coupled 
Filter-In Coupled 
 
Disp. Freq* Vel. 
Freq.* Vel. Freq. Vel. Freq. Vel. Freq. Vel. Freq. 
Point 
Position 
Mils  CPM  In/Sec  CPM  Mils CPM  Mils CPM  Mils CPM  Mils CPM 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
Horizontal 
 
 
 
 
 
 
 
 
 
 
 
 
Vertical 
 
 
 
 
 
 
 
 
 
 
 
 
 
Axial 
 
 
 
 
 
 
 
 
 
 
 
 
*Dominant Frequency 
 
Before vibration difficulties are reported, accurate vibration readings should be taken and consideration given to the following:
 
1) How does vibration level at center line of motor  
compare to that at motor feet and foundation? 
5) Does vibration level change when mounting bolts are loosened 
one at a time?  Do feet distort when bolts are loosened? 
2) Is motor on a fabricated base or grouted in concrete? 
3) When power is cut, does the vibration decay 
immediately or does it gradually die away? 
4) Is there a large shim pack under motor feet? 
6) Is motor for coupled or belt-drive use?  Is a coupling used on a 
long shaft motor? If so, how long is the key and what is the 
length of the coupling?  
7) Is there a resonant condition in the system which can be 
checked by a hammer test?