Battery connection
N.B.
To start the generator it is necessary to use a 12VDC battery, with a minmum 
capacity of 60Ah.
To start the generator, connect it to the positive pole of the vehicle’s battery 
with a sheathed cable of a suitable cross-section as shown in the table. The 
ground cable must have the same cross-section and be connected or as 
shown in the figure to the side or from the inserts to the frame of the vehicle. 
Make sure that the contact is good. If necessary remove paint or rust from 
the surface of the frame and protect the connection with grease. 
To protect the DC wiring use a 100 Amp fuse closed to the plus pole 
of the battery.
External control panel connection
Choose the desired position inside the vehicle, use the extension 
lead (supplied) to connect the external control panel to the internal 
control panel of the generator.
(+) Plus
pole
(-) negative
pole