         Important
Old  oil  moust  not  be  disposed  of  in  the  environment,  but  left 
to a station specialised in the disposal and/or recycling of the 
same, respecting the laws in the country where the operations 
are carried out.
Use oil recommended for 4-stroke Diesel engines of these types: 
CCMC-D4-D5-PD2 or API-CD-CE-CF-CG or SHPD (this indication is 
on the oil can).
SAE 10W-30 oil is recommended for general use at all temperatures. 
If  you  use  monograde  oil,  choose  the  appropriate  viscosity  on  the 
basis of the average temperature of the place where the generator is 
installed.
To drain the old oil easier you should run the generator for roughly 3/5 
minutes, in this way the oil is more fluid and will drain better through the 
drain tube when you remove the drain plug. Refill the generator with oil 
of the recommended type, through the oil filler.
The quantity of oil is:
 
 
    
 
3.3   Extraordinary maintenance
For some maintenance operations there is the possibility of pulling 
the generator out by sliding the entire bottom of the generator on 
the guides fixed to the sidewalls of the casing. To set the gene-
rator basis free loosen the harness and unscrew the 4 fastening 
screws. The generator unit will be extractable by ¾ of its depth. 
To come to a complete extraction put the generator basis on firm 
ground to protect it against possible falls and unscrew the 2 limit 
stop screws. Alternatively tighten the generator basis inserting 
screws in inner position.
Changing the oil
         Warning
 
Hot oil can burn your skin!
 
Check the oil level with the engine turned off.
122
104
86
68
50
32
14
-4
-22
-40
50
40
30
20
10
0
-10
-20
-30
-40
°F
°C
5W/30
5W/40
10W
10W/30
10W/40
15W/40
20W/20
30
40
OIL : SAE
Oil drain plug
1.1 Litres