Roland MC-909 用户手册

下载
页码 180
 
129
System
 
Menu
 
Sound
 
Here you can specify the tuning and how the sound is to be produced.
 
Sampling
 
Here you can make sampling-related settings.
Device ID
17–32
Device ID number of a systemexclusive message on the MC-909
A system exclusive message can only be received if the device number included in the message matches 
the device ID number set up on the receiving MIDI equipment. Using this function enables different Sys-
tem Exclusive messages to be received by more than one MC-909 unit at the same time.
* At the factory settings, the device ID number is set to “17.”
Receive Program 
Change
OFF, ON
Specifies whether or not each part will receive program changes. When this is “OFF,” program changes will 
not be received.
Receive Bank Se-
lect
OFF, ON
Specifies whether or not each part will receive bank select messages. When this is “OFF,” bank select mes-
sages will not be received.
Receive Exclu-
sive
OFF, ON
Specifies whether or not each part will receive system exclusive messages. When this setting is “OFF,” sys-
tem exclusive messages will not be received.
 
Parameter
Range
Explanation
[F1 (Sound/Tune)]
 
Master Tune
415.3–466.2 Hz
Adjusts the overall tuning of the MC-909.
The setting expressed as the frequency played by the A4.
Master Level
0–127
Adjusts the volume of the entire MC-909.
Output Gain
-12– +12 dB
Adjusts the output gain from the MC-909’s Analog Out and Digital Out.
Metronome Level
0–10
Adjusts the volume of the metronome.
Master Key Shift
-24– +24
Shifts the overall pitch of the MC-909.
Patch Remain
OFF, ON
Specifies whether currently sounding notes will continue sounding when another patch or 
rhythm set is selected (ON), or not (OFF).
 
[F2 (Sound Control)]
 
Rhythm Octave 
Switch
OFF, ON
Specifies the [OCT +/-] buttons will have effect when a rhythm set is assigned to current part 
(ON), or not (OFF). 
Resonance Limiter
50–127
Specifies the range in which the [RESONANCE] knob can be adjusted.
As this setting is increased, the variable range of the [RESNANCE] knob will increase. 
LFO Morphing 
Switch
OFF, ON
Specifies whether LFO1 Waveform will be modified smoothly by the knob (ON) or not (OFF).
 
Parameter
Range
Explanation
[F1 (Sampling)]
 
Default File Type
WAV, AIFF
File format used when saving a sample
Preset Default Load
OFF, ON
Specifies whether the preset samples will be loaded into memory at power-on (ON) or not 
(OFF).
Sample Default Load
OFF, ON
Specifies whether the samples of the user area and memory card will be loaded into mem-
ory at power-on (ON) or not (OFF).
Pre Sample Time
0–1000 ms
The length of sound preceding the moment at which sampling was manually or automati-
cally initiated that will be captured in the sample
This lets you prevent the attack portion of the sound from being omitted from the sample.
Trigger Level
0–7
Volume level at which sampling will begin when Auto Trig is ON
A setting of 0 is the minimum.
Gap Time
500, 1000, 1500, 2000 ms
Length of silence at which the sample will be divided
Whenever there is a silent region longer than the specified time, the sample will be divid-
ed at that point, and the next sample number will be assigned to the sound that follows.
* This parameter is valid only when you are using Auto Divide Sampling.
External Source Select
LINE-L-R, LINE-L, 
DIGI-OPT, 
DIGI-COAX, MIC
Input source of the external input sound
 
LINE-L-R:
 
 INPUT jacks L/R (stereo)
 
LINE-L:
 
 INPUT jack L (mono)
 
DIGI-OPT:
 
 Digital Input (Optical)
 
DIGI-COAX:
 
 Digital Input (Coaxial)
 
MIC:
 
 INPUT jack (mono, mic level)
Trimming Switch
OFF, ON
If this is turned on, the Start point and End point settings will be automatically adjusted af-
ter sampling is performed, so any silent portions at the beginning or end of the sampled 
sound are excluded.
 
Parameter
Range
Explanation
MC-909_Ref_e.book 129 ページ 2005年3月1日 火曜日 午後3時29分