Roland XV-5080. 用户手册

下载
页码 312
110
Chapter 3 Selecting Output Jacks
Example of Settings
Assigning Different Output 
Destinations for the Tones in a Patch
In this example, let’s suppose we have a Patch composed of 
four Tones, and we are outputting Tone 1 from the A 
OUTPUT jacks, Tone 2 from the B OUTPUT jacks, Tone 3 
from the INDIVIDUAL 5 jack, and Tone 4 from the 
INDIVIDUAL 6 jack. The Chorus and Reverb are output 
from the B OUTPUT jacks.
First, set the output destination for each Tone.
1. Select the Patch you wish to set.
2. Press [F6 (Effects)].
3. Press [F1 (General)] to call up the PATCH Effects General 
page.
4. Use TONE SELECT [1]–[4] to select the Tone you wish to 
set up.
5. Press [
]/[
]/[
]/[
] to move the cursor to 
the parameter you wish to set, and rotate the VALUE 
dial, or press [INC] or [DEC] to set the value as follows.
Tone Output Tone Dry
Tone Chorus Tone Reverb 
Assign
 Send Level
Send Level
Send Level
Tone 1
A
127
100
100
Tone 2
B
127
100
100
Tone 3
5
127
100
100
Tone 4
6
127
100
100
The Chorus and Reverb send levels can be set to any value 
you wish other than 0.
6. Press [EXIT] to return to the PATCH PLAY page.
7. Press [F1 (Common)].
8. Press [
]/[
] to move the cursor to Output Assign.
9. Turn the VALUE dial or press [INC]/[DEC] to select 
“TONE.”
10. Press [EXIT] to return to the PATCH PLAY page.
Next, select the Chorus output destination and set its overall 
level.
11. Press [F6 (Effects)].
12. Press [
]/[
]/[
]/[
] to move the cursor to 
Chorus Output Assign.
13. Turn the VALUE dial or press [INC]/[DEC] to select “B.”
14. Press [
]/[
]/[
]/[
] to move the cursor to 
Chorus Level.
15. Turn the VALUE dial to select “100.”
16. Press [
]/[
] to move the cursor to Chorus Output 
Select.
17. Turn the VALUE dial or press [INC]/[DEC] to select 
“MAIN.”
Finally, select the Reverb output destination and set its 
overall level.
18. Press [
]/[
]/[
]/[
] to move the cursor to 
Reverb Output Assign.
19. Turn the VALUE dial or press [INC]/[DEC] to select “B.”
20. Press [
]/[
]/[
]/[
] to move the cursor to 
Reverb Level.
21. Turn the VALUE dial to select “100.”
22. Press [EXIT] to return to the PATCH PLAY page.