Roland XV-5080. 用户手册

下载
页码 312
186
Chapter 7 Loading a Variety of Data
10. Turn the VALUE dial or press  [
] or [
]  to select the 
file to be loaded and press [F5 (Mark)]; a “✔” is added.
* Press [F4 (Mk All) if you want to set markers for all files. 
Press it again to remove all markers.
The files can also be sorted. Press [F3 (Sort)] to open the 
window for selecting the sorting preferences. Turn the 
VALUE dial or press [
] or [
] to select the sort type, 
then press [F6 (OK)].
Without:
Files are displayed in the order in which they 
have been saved.
Name:
Files are sorted by file name, in ascending order.
Size
:
Files are sorted in ascending order of file size.
Size
:
Files are sorted in descending order of file size.
11. Press [F6 (Select)]
The total memory used by the marked files is displayed.
* After checking the amount of memory, if you find you cannot 
load to the SIMM, follow the procedure in Step 10 to reset the 
markers once more.
12. Press [F6 (Load)].
When selecting Volume, Performance, or Patch files, a 
message asking “Overwrite in User Group. OK?” appears 
with a window in which the number and name of the User 
Group Patch or Performance is shown.
fig.07-009.e_70
* To cancel the operation, press [EXIT].
* When loading Patches or Performances, you can specify the 
load-destination Patch or Performance number in this 
window.
13. To overwrite while loading, press [F6 (OK)]. If you want 
to load to an empty location in the User Group, press [F5 
(NxtUsr)].
* If there is no space available in the User Group, “User 
Performances (Patches) Full    Choose User location and OK to 
overwrite” is displayed. 
In this case, press [F4 (JmpDel) to display the Delete screen, 
then proceed to delete a Performance or Patch.
14. A window appears, in which you can select either to 
overwrite the data (Partial or wave) on the SIMM (OK), 
or add to the data (Append).
* To cancel the operation, press [EXIT].
* If there is no available free space open in the SIMM, then press 
[F4 (JumpDel) to display the Delete page; you can then delete 
an unneeded Partial or wave.
* You can load a maximum of 4,096 Partials and 8,192 samples 
(if this does not exceed the capacity of the installed SIMM).
15. When loading has been completed, the File Selection 
page will reappear.
fig.07-010.e_70
You can check the tone of sample, .wav, .aif, and other such 
wave data files by pressing the VOLUME knob when 
selecting them.
* When loading Volume, Performance, Patch, Partial, and 
Program data, the lowermost file is loaded with it.
Free Area
SIMM
This displays the amount of free space in the SIMM.
Disk
This displays the free disk space remaining in the connected 
SCSI device.
Marked
The number and size of marked files to be processed are 
displayed.