Roland SP-606 用户手册

下载
页码 104
 
87
 
Troubleshooting
 
This section provides points to check and actions to take when 
the SP-606 does not function as you expect. Refer to the 
appropriate section for the problem you are experiencing.
If you find the screen display difficult or impossible to read, 
hold down [
 
KNOB ASSIGN
 
] and turn the 
 
VALUE
 
 dial to 
adjust the contrast.
 
No Sound/Insufficient Volume
 
Is the SP-606 correctly connected to your external 
equipment?
 
 
Could your audio cables be broken?
Could you be using a cable with a built-in resistor?
 
Use connection cables that do not have built-in resistors (such 
as the Roland PCS series).
 
Could the volume be lowered on the connected amp 
or mixer?
 
Adjust the volume to an appropriate level.
 
Could the volume of the SP-606 be too low?
 
Adjust the volume to an appropriate level.
 
Is there sound from the headphones?
 
If you hear sound from the headphones, the problem lies in a 
broken cable or in the amp or mixer that is connected. Check 
the connections and the connected devices. (p. 20)
 
In the MASTER screen, could “In Level,” “Low Gain,” 
or “High Gain” be lowered?
 
Adjust the various levels in the 
 
MASTERING
 
 screen 
 
Is the SP-606 in External mode?
 
 
Specific Pads Do Not Sound
 
Could the level of the sample be lowered?
 
 
Try turning off the MFX1 and MFX2 switches.
 
If you now hear sound, it may be that the level was being 
constrained by the MFX parameters, or that the MFX type was 
set to “
 
ENVELOPER (PAD)
 
.” Adjust the parameters to 
appropriate settings. If the MFX type is “
 
ENVELOPER 
(PAD)
 
,” striking a pad will apply an envelope so that the 
sound will be heard.
 
The Sound Stops Unexpectedly
 
Could a Mute Group be specified?
 
 
Could “Trig Mode” be set to ALTERNATE?
 
If “Trig Mode” is set to 
 
ALTERNATE
 
, the sample will 
alternately play or stop each time you strike the pad. If you 
want the sample to sound each time you strike the pad, set 
“Trig Mode” to 
 
GATE
 
 or 
 
SHOT
 
 
The Sound Does Not Stop
 
Could “Trig Mode” be set to SHOT?
 
If “Trig Mode” is set to 
 
SHOT
 
, the sample will play all the way 
to its end, so that for a long sample it may seem that the sound 
does not stop. If you set “Trig Mode” to 
 
ALTERNATE
 
, the 
sample will alternately play or stop each time you strike the 
pad. Or, if you set “Trig Mode” to 
 
GATE
 
, the sample will 
 
Could the Loop setting of the sample be turned on?
 
 
Can’t Control the Volume by Varying 
Your Striking Force on the Pads
 
Could “Pad Velocity” be set to a fixed setting?
 
If you want to control the volume by varying your striking 
force on the pads, you must set “Pad Velocity” to 
 
REAL
 
 
The Screen Display Is Not 
Visible, or Is Difficult to Read
Problems When Playing 
Sounds
SP-606_e.book 87 ページ 2004年6月21日 月曜日 午前10時8分