Roland FR-7 用户手册

下载
页码 114
MIDI functions | MIDI parameters for the various sections/parts
86
r
FR-7/FR-5 V-Accordion
MIDI parameters for the various sections/parts
The MIDI parameters discussed below belong to separate groups and are saved for the corresponding sections. This 
means that each Set can use different MIDI settings and thus control external MIDI devices in various ways. If you are 
serious about using the FR-7/FR-5’s MIDI potential, carefully read the following before editing the available parameters.
Important remarks
The parameters discussed below apply to the transmis-
sion of MIDI data (“TX”) and therefore only to MIDI 
messages that are generated when you yourself play on 
the FR-7/FR-5.
Bear in mind that the MIDI messages discussed below 
are only executed by an external tone generator if its 
MIDI receive (“RX”) channel is set to the number you 
assigned to the section in question (page 81). 
Sections
The parameters discussed here are available in the fol-
lowing sections: Treble, Bass (and Chord, which is con-
sidered a separate section on the MIDI level), Free Bass, 
Orchestra, Orchestra Bass, Orchestra Chord and Orches-
tra Free Bass.
The reason why they are included in the section param-
eters rather than the MIDI group is that the MIDI group 
applies to the entire FR-7/FR-5 (all sections, all Sets), 
while the parameters below can vary from Set to Set. 
You can change the way external MIDI devices are con-
trolled simply by selecting another Set – and still use 
exactly the same internal sounds: after setting the vari-
ous section parameters (and saving them), copy the Set 
to a different memory (page 74) and only change the 
MIDI parameters.
Procedure for setting these parameters
To access the parameters discussed below, proceed as 
follows:
(1) Select the parameter group of the section you wish 
to edit.
Either press the [MENU÷WRITE] button and select the 
parameter group with the [DATA÷ENTER] knob or use 
the JUMP TO function (press and hold the 
[EXIT÷JUMP] button, then enter the parameter 
address using the Treble registers, see p. 38).
(2) Select the parameter. 
(If you used the JUMP TO function above, the param-
eter is already selected.) Press the [MENU÷WRITE] 
button and select the parameter with the 
[DATA÷ENTER] knob.
The following are MIDI functions:
(3) Press the [DATA÷ENTER] knob to select “MESSAGE” 
(left entry), then turn it to select the parameter 
you want to set.
The parameters are explained below.
(4) Press the [DATA÷ENTER] knob to select “VALUE” 
(right entry), then turn it to set the desired value. 
(Press [DATA÷ENTER] again, select another parame-
ter and edit its value.)
(5) Press [EXIT÷JUMP] to return to the Main page.
(6) Save your changes:
• Press and hold the [MENU÷WRITE] button until the 
following page appears:
• Rotate the [DATA÷ENTER] knob (or use the [UP]/
[DOWN] buttons) to select “ALL”.
Selecting this option has the advantage that you can 
wait until all sections have been edited before saving 
them in one go (for the entire Set).
• Press the [DATA÷ENTER] knob to confirm your selec-
tion.
• If necessary, rotate the [DATA÷ENTER] knob to select 
another destination Set (1~40).
• Press the [MENU÷WRITE] button to save your 
changes. The display briefly shows a confirmation:
• Press the [EXIT÷JUMP] button to return to the Main 
page.
Parameters
Here are the MIDI parameters that can be set for each 
register of a section separately. Remember that they 
only apply to MIDI messages the FR-7/FR-5 sends to 
external devices. Do not forget to select the register 
whose MIDI parameters you wish to edit before actu-
ally changing them.