Chapter 4 Other Functions
 
fig.04-12.e
 
Local Control ON: The keyboard and the internal sound 
generator are in a linked state.
 
fig.04-13.e
 
Local Control OFF: The keyboard and the internal sound 
generator are in an unlinked state. No sound will be 
produced by the keyboard when it is played.
 
fig.04-14.e
 
* When connecting a unit in the Roland MT series, you don’t 
need to switch off Local Control. MT units transmit Local Off 
messages when their power is switched on. If you first switch 
on the FP-5, then the MT-series device, Local Control is 
automatically switched off on the FP-5.
 
1.
 
Switch to Function mode, and press the [Song] 
button.
 
fig.04-15
 
2.
 
Press the [-] or [+] button to switch Local Control 
on and off.
 
Setting the MIDI Out Mode
 
By setting the MIDI Out Mode, you can select to have a more 
suitable (to the external MIDI device) selection of MIDI data 
be output from the MIDI Out connector when you make tone 
changes on the FP-5. 
Four settings for the MIDI Out Mode are available. 
“MIDI Out Mode 1” is the power-up default setting. 
 
1.
 
Switch to Function mode, and press the [Play/
Stop] button.
 
fig.04-17
 
2.
 
Press the [-] or [+] button to select the MIDI Out 
Mode.
(1)
MIDI
MIDI
MIDI
MIDI
(2)
IN
IN
OUT
OUT
Sequencer
Memory
Sound
Generator
Each note played
is sounded twice
Thru function On
Local On
Local On
Sound is emitted
Sound Generator
Local Off
No sound produced
Sound Generator
flashes in red
 
Indication
 
Descriptions
 
1
 
MIDI Out Mode 1
This setting is suitable for the connection of 
sequencers. The MIDI information (for exam-
ple: Bank select, Program Change, Settings of 
Effects, and so on) is output from the MIDI 
Out connector when you make a tone change 
on the FP-5. 
 
2
 
MIDI Out Mode 2
This setting is suited for connecting to a sound 
module.
 
 
 
The MIDI information (for example: 
Bank select) is not output from the MIDI Out 
connector when you make a tone change on 
the FP-5.
 
3
 
MIDI Out Mode 3
You can transmit performance data recorded 
with the FP-5.
Additionally, the MIDI messages that are out-
put have the same content as those in MIDI 
Out Mode 1.
 
4
 
MIDI Out Mode 4
The MIDI messages that are output have the 
same content as those in MIDI Out Mode 3. 
However, these are not transmit to FP-5’s 
sound module.
Additionally, the local control is switched to 
flashes in red