Roland SH-01 用户手册

下载
页码 21
4
MIDI Implementation
l
Universal Realtime System Exclusive Messages
m
Master Volume
Status
Data byte                                         
Status
F0H
7FH, 7FH, 04H, 01H, llH, mmH
F7H
Byte
Explanation                                                         
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
01H
Sub ID#2 (Master Volume)
llH
Master Volume lower byte
mmH
Master Volume upper byte
F7H
EOX (End Of Exclusive)
*  The lower byte (llH) of Master Volume will be handled as 00H.
*  The MASTER LEVEL parameter (System Parameter) will change.
m
Master Fine Tuning
Status
Data byte                                         
Status
F0H
7FH, 7FH, 04H, 03H, llH, mmH 
F7H
Byte
Explanation                                                         
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
03H
Sub ID#2 (Master Fine Tuning)
llH
Master Fine Tuning LSB
mmH
Master Fine Tuning MSB
F7H
EOX (End Of Exclusive)
mm, ll: 00 00H - 40 00H - 7F 7FH (-100 - 0 - +99.9 [cents])
*  The MASTER TUNE parameter (System Parameter) will change.
l
Data Transmission
This instrument can use exclusive messages to exchange many varieties of internal 
settings with other devices.
The model ID of the exclusive messages used by this instrument is 00H 00H 41H.
m
Data Request 1   RQ1 (11H)
This message requests the other device to transmit data. The address and size indicate 
the type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it is able 
to transmit data, and if the address and size are appropriate, the requested data is 
transmitted as a Data Set 1 (DT1) message. If the conditions are not met, nothing is 
transmitted.
status
data byte                                                                   status
F0H
41H, dev, 00H, 00H, 41H, 11H, aaH, bbH, 
ccH, ddH, ssH, ttH, uuH, vvH, sum
F7H
Byte
Remarks                                               
F0H
Exclusive status
41H
ID number (Roland)
dev
device ID (dev: 10H - 1FH, 7FH)
00H
model ID #1 (SH-01)
00H
model ID #2 (SH-01)
41H
model ID #3 (SH-01)
11H
command ID (RQ1)
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
ssH
size MSB
ttH
size
uuH
size
vvH
size LSB
sum
checksum
F7H
EOX (End Of Exclusive)
*  The size of data that can be transmitted at one time is fixed for each type of data. 
And data requests must be made with a fixed starting address and size. Refer to the 
address and size given in “Parameter Address Map” (p. 8).
*  For the checksum, refer to (p. 20).