Roland 04672434 用户手册

下载
页码 184
 
135
MASTER                                                                        Chapter 8 Parameter Guide
 
Chapter 8
 
CONTROL ASSIGN
 
Adjust these settings if you would like to use a pedal connected to 
the VB-99, or an external MIDI device (control source) to control 
parameters as you play.
You can set two parameters as targets to each control source.
 
*
Turn on the COSM bass, COSM amp, and effect that contains the 
parameter you wish to control.
 
MASTER
 
GK VOL (GK Volume)
 
Parameter/
Range
Explanation
 
SW
 
OFF, ON
This setting switches GK VOL on and off.
 
TARGET PARAMETER
 
This selects the parameter to be changed.
 
MIN (Minimum)
 
This sets the minimum value for the range in which the parameter 
can change.
The value differs depending on the parameter assigned for TARGET 
PARAMETER.
 
MAX (Maximum)
 
This sets the maximum value for the range in which the parameter 
can change.
The value differs depending on the parameter assigned for TARGET 
PARAMETER.
 
RANGE LOW, RANGE HIGH
 
Low: 0–126
High: 1–127
You can set the controllable range for target 
parameters within the GK Volume’s opera-
tional range. Target parameters are con-
trolled within the range set with RANGE 
LOW and RANGE HIGH. You should nor-
mally set RANGE LOW to 0 and RANGE 
HIGH to 127.
 
GK S1, S2 
(DOWN/S1, UP/S2 Switch)
 
Parameter/
Range
Explanation
 
SW
 
OFF, ON
This setting determines whether control 
using DOWN/S1 and UP/S2 is switched on 
or off.
 
TARGET PARAMETER
 
This selects the parameter to be changed.
 
MIN (Minimum)
 
This sets the minimum value for the range in which the parameter 
can change.
The value differs depending on the parameter assigned for TARGET 
PARAMETER.
 
MAX (Maximum)
 
This sets the maximum value for the range in which the parameter 
can change.
The value differs depending on the parameter assigned for TARGET 
PARAMETER.
 
MODE
 
Specify how the value will change in response to an operation.
 
*
When the DOWN/S1, UP/S2 POS of the GK SETTING is set to 
REVRSE position, the function of DOWN/S1, UP/S2 will be 
reversed.
*
When KEY/BPM/AMPCTL:BPM TAP, FX–DELAY(HOLD)–
REC, or FX–DELAY(HOLD)–STOP is set for the TARGET 
PARAMETER, control is available regardless of whether DOWN/S1 
or UP/S2 is pressed. In this case, the MODE setting is disabled.
 
S1: DEC
S2: INC
S1 will decrease the value, and S2 will in-
crease it.
S1: INC
S2: DEC
S2 will decrease the value, and S1 will in-
crease it.
S1: MIN
S2: MAX
The value will be at MIN when S1 is 
pressed.
The value will be at MAX when S2 is 
pressed.
S1: MAX
S2: MIN
The value will be at MAX when S1 is 
pressed.
The value will be at MIN when S2 is 
pressed.
VB-99_e.book 135 ページ 2008年8月18日 月曜日 午後1時10分