Roland 04672434 用户手册

下载
页码 184
 
141
MASTER                                                                        Chapter 8 Parameter Guide
 
Chapter 8
 
*1
The TRIGGR, TIME, and CURVE parameters are enabled when 
the SOURCE parameter is set to INTRNL PEDAL.
*2
The RATE and FORM parameters are enabled when the 
SOURCE parameter is set to WAVE PEDAL.
*3
The INPUT SENS parameter is enabled when the SOURCE 
parameter is set to INPUT LEVEL.
 
Parameter/
Range
Explanation
 
MAX (Maximum)
 
This sets the maximum value for the range in which the parameter 
can change.
The value differs depending on the parameter assigned for TARGET 
PARAMETER.
 
SW MODE (Switch Mode)
 
This sets the behavior of the value each time the switch is operated.
MOMENT
The setting is normally OFF (minimum val-
ue), switching to ON (maximum value) 
while the footswitch is held down.
LATCH
The setting alternately switches to OFF 
(minimum value) and ON (maximum val-
ue) each time the footswitch is pressed.
 
RANGE LOW, RANGE HIGH
 
Low: 0–126
High: 1–127
You can set the controllable range for target 
parameters within the source’s operational 
range. Target parameters are controlled 
within the range set with RANGE LOW and 
RANGE HIGH. You should normally set 
RANGE LOW to 0 and RANGE HIGH to 
127.
 
TRIGGR (Trigger)
 
This sets the trigger that activates the internal pedal. *1
PATCH CHANGE
Functions when patches are switched.
GK VOL
Functions when the divided pickup’s vol-
ume knob is adjusted.
GK S1, S2
Functions when the divided pickup’s 
DOWN/S1 or UP/S2 switch position is 
changed.
CTL1–CTL4
Functions when the CTL 1, 2 buttons or foot 
switch connected to CTL 3,4 jack are operat-
ed.
EXP PEDAL
Functions when the expression pedal con-
nected to EXP PEDAL jack are operated.
D BEAM V, H
Functions when the vertical or horizontal 
position is detected by the D Beam control-
ler.
RIBBON ACT, POS
Functions when the ribbon controller is op-
erated by touch or when the position is de-
tected.
FC-300 EXP1, EXP2
Functions when the FC-300’s EXP PEDAL 1 
or 2 is operated.
FC-300 CTL1, CTL2
Functions when the FC-300’s CTL1 or CTL2 
is operated.
FC-300 E3/C3, CTL4, 
E4/C5, CTL6, E5/C7, 
CTL8
Functions when a pedal connected to the 
FC-300’s E3/C3, CTL4, E4/C5, CTL6, E5/
C7, or CTL8 jacks is operated.
 
TIME
 
0–100, 
 
BPM –
 
Adjusts the amount of time for the internal 
pedal to shift from the fully released posi-
tion (pedal toe raised) to the fully depressed 
position (pedal toe pressed down). *1
 
Parameter/
Range
Explanation
 
CURVE
 
This selects one of the three types that determines how the internal 
pedal should change. *1
 
RATE
 
0–100, 
 
BPM –
 
This determines the time spend for one cycle 
of the wave pedal. *2
 
FORM
 
This selects one of the three types that determines how the wave 
pedal should change. *2
 
INPUT SENS
 
0–100
This adjusts the input sensitivity when IN-
PUT LEVEL is selected for SOURCE. *3
 
DIRECT EDIT F1–F6
 
Parameter/
Range
Explanation
 
This assigns functions to the function buttons operable in the Play 
screen and the [F1]–[F6] or F1–F6 knobs.
 
TARGET PARAMETER
 
This selects the parameter to be changed.
LINEAR
SLOW RISE
FAST RISE
SAW
TRI
SIN
VB-99_e.book 141 ページ 2008年8月18日 月曜日 午後1時10分