GLOBAL                                                                        Chapter 8 Parameter Guide
 
Chapter 8
 
EQ MAIN (Equalizer Main), 
EQ SUB (Equalizer Sub)
NS (Noise Suppressor)
REVERB
 
GLOBAL
 
Parameter/
Range
Explanation
 
SETTING1–10
 
1–10
This selects the SETTING to be set.
 
NAME
 
This sets the name for the SETTING (up to eight characters).
INSERT
Insert a space at the cursor location.
DELETE
Delete a character. The characters that fol-
low get shifted to the left.
SPACE
Input a space at the cursor location.
A0!
Switch between uppercase letters, numbers, 
and characters.
A<=>a
Switch between uppercase letters and low-
ercase letters.
 
MAIN OUTPUT SELECT
 
This selects the type of device to be connected.
AMP WITH TWEETER
Use this setting when connecting to a tweet-
er-equipped bass amp.
AMP NO TWEETER
Use this setting when connecting to a bass 
amp that has no tweeter. The high-frequen-
cy range is adjusted.
LINE/PHONES
Use this setting when using headphones or 
connecting directly to a PA system or multi-
track recorder.
 
Parameter/
Range
Explanation
 
MAIN EQ (Main Equalizer), 
SUB EQ (Sub Equalizer)
 
A four-band equalizer with high and low ranges is provided.
 
EQ (MAIN) is applied to the output from MAIN OUT; EQ 
(SUB) is applied to the output from SUB OUT.
 
MAIN EQ SW (Main Equalizer Switch), 
SUB EQ SW (Sub Equalizer Switch)
 
OFF, ON
Turns the EQ effect on/off.
 
TOTAL GAIN
 
-12–+12dB
Adjusts the volume before the equalizer.
 
LOW GAIN
 
-12–+12dB
Adjusts the low frequency range tone.
 
HIGH GAIN
 
-12–+12dB
Adjusts the high frequency range tone.
 
LOW MID FREQ (Low Middle Frequency)
 
20Hz–10.0kHz
Specifies the center of the frequency range that will 
be adjusted by the LOW MID GAIN.
 
LOW MID Q (Low Middle Q)
 
0.5–16
Adjusts the width of the area affected by the EQ 
centered at the LOW MID FREQ. 
Higher values will narrow the area.
 
LOW MID GAIN (Low Middle Gain)
 
-12–+12dB
Adjusts the low-middle frequency range tone.
 
HIGH MID FREQ (High Middle Frequency)
 
20Hz–10.0kHz
Specifies the center of the frequency range that will be 
adjusted by the HIGH MID GAIN.
 
Parameter/
Range
Explanation
 
HIGH MID Q (High Middle Q)
 
0.5–16
Adjusts the width of the area affected by the EQ 
centered at the HIGH MID FREQ. 
Higher values will narrow the area.
 
HIGH MID GAIN (High Middle Gain)
 
-12–+12dB
Adjusts the high-middle frequency range tone.
 
Parameter/
Range
Explanation
 
NS (Noise Suppressor)
 
-20–20dB
This controls the global threshold level for 
the noise suppressor settings in each patch. 
This feature is effective when you connect a 
different bass or for adjusting for changes in 
noise levels in the performance venue. It 
does not affect the settings in each individu-
al patch.
 
To use the settings contained in the 
individual patches, set this to 0 dB.
 
Parameter/
Range
Explanation
 
REVERB
 
0–200%
This controls the global reverb level for the 
reverb settings in each patch. Adjusting this 
reverb level is effective for adjusting to the 
acoustics of the performance space. It does 
not affect the settings in each individual 
patch.
 
To use the settings contained in the 
individual patches, set this to 100%.
 
Parameter/
Range
Explanation
VB-99_e.book 157 ページ 2008年8月18日 月曜日 午後1時10分