Excalibur electronic A-MNL-NIOSPROG-01.1 用户手册

下载
页码 122
46
Altera Corporation
32-Bit Instruction Set
CMPI
Compare Immediate
Operation:
∅ ← RA – (0x00.00 : K : IMM5)
Assembler Syntax:
CMPI & %rA,IMM5
Example:
Not preceded by PFX: 
CMPI %i3,24 ; compare %i3 to 24
Preceded by PFX:
PFX %hi(1000)
CMPI %i4,%lo(1000)
Description:
Not preceded by PFX: 
Subtract a 5-bit immediate value given by IMM5 from RA, and discard the result. 
Set the condition codes according to the subtraction. RA is not altered.
Preceded by PFX:
The Immediate operand is extended from 5 to 16 bits by concatenating the 
contents of the K-register (11 bits) with IMM5 (5 bits). The 16-bit immediate value 
(K : IMM5) is zero-extended to 32 bits and subtracted from RA. Condition codes 
are set and the result is discarded. RA is not altered.
Condition Codes:
Flags:
N: Result bit 31
V: Signed-arithmetic overflow
Z: Set if result is zero; cleared otherwise
C: Set if there was a borrow from the subtraction; cleared otherwise
Instruction Format:
Ri5
Instruction Fields:
A = Register index of RA operand
IMM5 = 5-bit immediate value
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
1
0
1
IMM5
A
N
V
Z
C