Siemens 020-011 用户手册

下载
页码 79
 
 
 
Industry Sector, IA&DT
 
 
 
 
SCE Training Curriculum 
Page 37 of 79  
To be used only in Educational and R&D  Facilities 
TIA Portal Module 020-011, Edition 04/2014
 
 
                                                 Unrestricted / © Siemens AG 2014. All Rights Reserved
 
SCE_EN _020-011_R1404_Startup Programming with SIMATIC S7-1500 
 
 
 
 
7. 
Sample Task Press Control 
 
For our first program, we are programming a press control. 
 
A press with a protection device can only be started with a START button S3 when the protection grid  is 
closed and the EMERGENCY STOP button (NC contact) is not operated. The state Protection grid 
closed is monitored with a sensor B1. 
If this is the case, a 5/2 way valve M0 is set for the press cylinder to press a plastic figure. 
The press is to power up again when the start button S3 is operated, the EMERGENCY STOP button 
(NC contact) is operated or the sensor Protection grid  B1 no longer responds. 
 
 
Assignment list: 
 
Address 
Symbol 
Comment 
 
%I 0.1 
E-STOP 
Feedback EMERGENCY STOP (NC) 
%I 0.3 
S3 
Start button (NO) 
%I 0.4 
B1 
Sensor protection grid closed (NO) 
%Q 0.0 
M0 
Extend cylinder A 
 
 
EMERGENCY STOP