Tektronix 070-9197-00 用户手册

下载
页码 72
Syntax and Commands
PS2520G and PS2521G Programmer Manual
29
STATus:OPERation:CONDition? (Query Only)
Returns the contents of the OPERation register. The PS2520G and
PS2521G Programmable Power Supplies, however, do not use the
OPERation register to report any conditions.
Reading the OPERation register does not affect its contents.
!
!  returns 
STATus:OPERation:ENABle
Sets or returns the contents of the OPERation Enable Register. Even
though this is a 16-bit register, only 15 bits (bit 0 through bit 14) are
used. Bit 15 is always 0.
!  
!
 is an integer from 0 to 32767.
!   sets all 15 bits of the register
high.
!  returns  if all 15 bits of the register
are low.
Syntax
Returns
Examples
Syntax
Parameters
Returns
Examples