Alarm and fault messages 
4.2 Alarm and fault messagesAlarm and fault messagesAlarm and fault messages 
28 
92 
DC overvoltage protection has 
responded (or fuse (if installed) has 
tripped) 
Fault Overvoltage 
(lightning strike) has occurred 
93 
Fast Stop activated or overvoltage on 
medium-voltage transformer 
Fault 
Fast Stop button pressed, fault in cooling system 
of medium-voltage transformer 
94 
Profibus error 
Fault 
  
95 
Grid frequency outside tolerance 
Fault 
Phase sequence is anti-clockwise, grid failure, 
parameter setting error 
96 
Grid voltage outside tolerance 
Fault 
Grid voltage outside tolerance (possibly grid 
failure as well), voltage measurement error, 
parameter setting error 
97 
No checkback from DC link contactor 
or failure of cooling fan in the 
container 
Fault 
DC link contactor defective, signal cable 
defective, container fan defective 
98 
Symmetry fault in the PV field 
Fault 
Fault in at least one PV field string 
100 
Image in the display (WinCC) 
No fault 
(generated by the control unit) 
LED 
"ISO" 
 
flashing 
Insulation fault in the PV field (alarm) 
Alarm 
Cable damaged, module damaged, rain 
LED 
"ISO" lit 
steadily 
Insulation fault in the PV field (fault) 
Fault 
Cable damaged, module damaged, rain