Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 
Page 4                                      1/26/2005   Rev 1.0.01 
There are 2 modes after data processing unit powers up: 
1. Running Mode: In this mode, B500 meter can perform TOU metering, 
demand calculating and load monitoring, and automatically display data 
at given time as programmed. 
2. Programming  mode: A0 will switch to this mode after holding reset 
button for 8 seconds. In this mode, LCD will display message “PRG”. It 
will only process energy counting, demand calculating and time-section 
switch only without handling other functions such as timing display or 
load monitoring. A0 will exit from this mode when reset button is 
pushed again, or exit automatically if no button was pushed for 4 
minutes. 
 
When data processing unit is running, LED will flash once an effective 
energy pulse is registered, no matter which mode it is in. 
 
2.1.2 Data display 
 
There are 2 types of data display modes: 
 
1) Timing display: user can choose from 4 types of time intervals. The 
display is automatic and can be used for routine monitoring. 
2) Inquiry display: User may continuously push button until the needed 
data is displayed. This can be used to check records in the meter. 
 
Detailed descriptions of three types of data display modes are as following: 
 
1) Timing display:  This mode is effective once programmed. If the 
display interval is set to 15 minutes, B500 will display data at minute 
of 0, 5, 15, 30 or 45 hourly. It stops automatically after all specified 
data have been displayed. Display time for each piece of data can be 
set independently from 1 to 99 seconds. If it needs more time to 
display all the data within one interval, meter will skip one display and 
will display the data at the next display time.  
2) Inquiry display: B500 will switch to this mode once display button is 
pushed. In this mode, display time of each data item extends sixty 
times longer. For example, if original display time is set as 8 seconds 
for each data, display time for the same data extends to 8 minutes 
now. Next data will be displayed once display button is pushed again. 
If display button is not pushed throughout the period when a data is 
displayed, meter will automatically switch to Timing Display Mode 
after data display finishes and will continue display of next data. 
 
 
Display Explanation 
 
Please see OBIS as reference. 
Meter 
number 
 
 
 
    OBIS 
ID 
1-0:0.0.0(1) 
Current active import energy sum   OBIS 
ID 1-1:1.8.0 
Current active export energy sum 
 
OBIS ID 
1-1:2.8.0