Modes of operation
DN540
Operator Manual
25
Figure 6: Compression - limiting signal level graphs
If a compression effect is required together with limiting of high level transients, two 
channels of the DN540 may be cascaded.  The output of Channel 1 (compression) is fed 
to the input of Channel 2 (limiting), which gives powerful two stage control over gain.
Figure 7: Limiting and compression graph
Below the compression threshold, the signal is unaltered.  In the example shown in 
Figure 7 “Limiting and compression graph”, the first threshold is compressed at a mild 
2:1 ratio.  Whereas, at the second threshold it is firmly limited at a ratio of 20:1.
Threshold level
Si
gnal le
ve
l
Limiting
Time
Unprocessed
Time
Si
gnal
 l
ev
el
signal
Threshold level
Input level (dB)
O
u
tp
ut le
ve
l (dB)
+20
+10
-10
-20
+10
+20
-10
-20
1:1
Compressor 2 threshold