Troubleshooting – Mechanical and Electrical Problems 
Trouble Probable 
Cause 
Remedy 
Machine will not 
start/restart or 
repeatedly trips 
circuit breaker or 
blows fuses. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
No incoming power. 
Verify unit is connected to power, on-
button is pushed in completely, and 
stop-button is disengaged. See page 
25. 
Overload automatic reset has not 
reset. 
When jointer overloads on the circuit 
breaker built into the motor starter, it 
takes time for the machine to cool 
down before restart. Allow unit to 
adequately cool before attempting 
restart. If problem persists, check 
amp setting on the motor starter 
inside the electrical enclosure. 
Jointer frequently trips. 
One cause of overloading trips which 
are not electrical in nature is too 
heavy a cut. The solution is to take a 
lighter cut. If too deep a cut is not the 
problem, then check the amp setting 
on the overload relay. Match the full 
load amps on the motor as noted on 
the motor plate. If amp setting is 
correct then there is probably a loose 
electrical lead. Check amp setting on 
motor starter. 
Building circuit breaker trips or fuse 
blows. 
Verify that jointer is on a circuit of 
correct size. If circuit size is correct, 
there is probably a loose electrical 
lead. Check amp setting on motor 
starter. 
Switch or motor failure (how to 
distinguish). 
If you have access to a voltmeter, you 
can separate a starter failure from a 
motor failure by first, verifying 
incoming voltage at 220+/-20 and 
second, checking the voltage 
between starter and motor at 220+/-
20. If incoming voltage is incorrect, 
you have a power supply problem. If 
voltage between starter and motor is 
incorrect, you have a starter problem. 
If voltage between starter and motor 
is correct, you have a motor problem. 
Motor overheated. 
Clean motor of dust or debris to allow 
proper air circulation. Allow motor to 
cool down before restarting. 
Motor failure. 
If electric motor is suspect, you have 
two options: Have a qualified 
electrician test the motor for function 
or remove the motor and take it to a 
qualified electric motor repair shop 
and have it tested.