Model g0705 (Mfg. since 09/09)
110v conversion
the  Model  g0705  can  be  converted  for  110v 
operation.  this  conversion  job  consists  of  dis-
connecting  the  machine  from  the  power  source, 
replacing  the  contactors  and  power  indicator 
lamp, and rewiring the motor. 
the  necessary  components  for  this  procedure 
can  be  purchased  in  the  Model  g0705  110v 
Conversion  Kit  (part  no.  p0705311)  by  calling 
grizzly Customer service at (800) 523-4777.
all wiring changes must be inspected by a quali-
fied  electrician  before  the  machine  is  connected 
to the power source. if, at any time during this pro-
cedure you need help, call grizzly tech support 
at (570) 546-9663.
to  rewire  the  model  g0705
 
for  110v  opera-
tion:
1.  disConneCt MaChine FroM poWer!
2.  remove the electrical box and motor junction 
box covers shown in 
figure 4.
3.  use  a  phillips  screwdriver  to  remove  all  of 
the wires that connect to the two contactors 
shown in 
figures & 6. if any of the wires 
are  not  clearly  labeled,  label  them  before 
removing to ensure that they will be replaced 
in the proper locations. refer to 
section 8: 
Wiring starting on page 45 for detailed wir-
ing diagrams.
L
1
L
L
L
L
L
L
L
L
4
3
7
7
6
6
4
4
3
2
2
4
4
8
8
4
4
7
5
5
5
5
N
N
N
N
N
N
N
N
N
PE
V2
V1
U2
U1
V2
V2
V1
V1
2T1
14NO
CONTACTOR
SIEMENS KM1 
CONTACTOR
SIEMENS KM2
22NC
32NC
44NO
13NO
21NC
31NC
43NO
6T3
A2
A1
A1
4T2
1L1
5L3
3L2
2T1
14NO
22NC
32NC
44NO
4
3
X1
X2
REV
POWER
INDICATOR
LAMP
STOP
BUTTON
FWD
EMERGENCY
STOP
BUTTON
2
1
2
1
3
4
13NO
21NC
31NC
43NO
6T3
A2
4T2
1L1
5L3
3L2
V1
U2
U2
U2
U1
PE
1
1
1
PE
GND
GND
Contactor Information
For 220V, Contactor Type 3TB41 22-OX, Coil Voltage 220V/60Hz/1PH, SIEMENS 
For 110V, Contactor Type 3TB41 22-OX, Coil Voltage 110V/60Hz/1PH, SIEMENS
(Contactor is wired the same for 110V/220V)
To Motor
To Plug
Control Panel (Viewed From Behind)
Electrical Box
12A
FUSE
Indicator Light Type XDJ2(J) 220V AC
Indicator Light Type XDJ2(J) 110V AC
(Indicator is wired the same for 110V/220V)
figure 5.
 Partial wiring diagram.
Contactors
figure 4.
 Cover locations.
Motor Junction 
Box Cover
electrical Box 
Cover
indicator lamp
indicator
lamp
figure 6.
 Removing contactors.