CONTROLS & THEIR FUNCTIONS 
 
1.  POWER OUTPUT INDICATOR 
When lit, this LED indicates that power is available for cutting. 
2.  ALARM INDICATOR 
When lit, this LED indicates that one of the alarms has triggered. At the same time the digital 
display (Ref. 3) shows the type of alarm, as shown in the table below, with instructions\for 
correcting the problem. In this condition the unit does not supply current. 
3.  DIGITAL DISPLAY 
This display operates in a number of ways: 
Display Volts or Amps – by pressing the V/A switch (5), you can read the voltage or amperage at 
the torch.  This is a momentary display 
Display Air Pressure – By pressing the bar switch (6) you can read the operating air pressure of 
they system.  
Error/Alarm Indications – If an error is present, the display will light showing the code of the error.  
The codes are shown below: 
DISPLAY 
ERROR or PROBLEM 
CORRECTION/RESET 
- - - 
Insufficient input voltage 
 
CUP 
The nozzle cap is not properly 
screwed on the torch 
Turn the unit OFF.  Tighten the nozzle 
cap on the torch correctly and turn the 
unit back ON  
HtA 
Unit is overheating 
Stop cutting – allow the unit to cool down.  
Alarm will reset after the unit has cooled 
down. 
ThA (Flashing) 
Unit is approaching 
overheating 
Stop cutting – allow the unit to cool down.  
Alarm will reset after the unit has cooled 
down. 
Air 
Insufficient air pressure 
Adjust air regulator to increase pressure.  
Check incoming air line. 
ScA 
Short circuit in output of unit 
Turn the unit OFF and turn back ON to 
reset 
LSF 
Arc blow out 
Check wear on electrode and nozzle.  
Replace if worn. If alarm continues, cycle 
the unit off and on. 
 
 
15