Wolfcraft 6155 用户手册

下载
页码 92
27
Introduction
A conveniently located Switch Box 
allows the operator to:
• turn the router ON and OFF from the 
front of the table
• simultaneously operate other devices 
such as a light or a vacuum
It also features a resettable, internal 
circuit breaker that protects your 
equipment against overloads.  See 
Figure 25.
PULL O
N
PUSH
 OFF
RESET
OUT
LETS
Electrical Hookup
Proper grounding diverts potentially 
dangerous electricity away from the 
operator.  The switch box is intended for 
use with a three-prong, grounded outlet.  
(See Figure 26, below.)  The switch 
box's electrical cord features an 
equipment-grounding connector and a 
grounding plug.  Insert the plug into an 
accommodating outlet that conforms to  
the National Electric Code (NEC) and all 
local electrical codes.
Figure 25
Figure 26
reset button
WARNING
 DO NOT MODIFY THE PLUG
If it does not fit correctly, a qualified electrician 
must install a compatible outlet.
AVOID THE RISK OF ELECTRICAL SHOCK
NEVER connect the equipment grounding 
connector (green wire) to a "hot" electrical 
terminal.  When repairing or replacing the 
electric plug or cord, DO NOT connect the 
grounding connector to a "hot" electrical 
terminal.
Consult a qualified electrician if you do not 
understand the grounding procedures, or if you 
are not sure whether the switch box is correctly 
grounded. 
REPLACE DAMAGED CORDS
Damaged and/or worn cords must be repaired 
or replaced immediately. 
Extension cords must be three-wire, 14 gauge 
or larger, with three-prong "male" plugs, and 
three hole "female" receptacles fabricated to 
accept the tool's plug.
The electrical outlets on the bottom of the 
switch box accept three-prong grounded plugs 
and the two-prong plugs of double insulated 
tools.
SWITCH BOX