3.4.  Diagnostics 
3.4.1. Service [All product configurations] 
To access onboard diagnostics from the local user interface, Xerox service representatives must enter a 
unique 4-digit password.  This PIN is the same for all product configurations and cannot be changed. 
For additional security, a Xerox authorized service representative can enable a “secure diagnostics” mode.  
In this mode, the service representative must enter two PINs to access onboard diagnostics.  When 
enabling the secure diagnostics mode for the first time, the service representative should change the PIN 
to something known only to him or his local team.  On subsequent logins, the secure diagnostics PIN must 
be entered followed by the standard diagnostics PIN in order to gain access to the diagnostics menu. 
 
3.4.2. Alternate Boot via Serial Port 
Alternate Boot (Alt-boot) is a means for the Portable Service Workstation (PSW) to directly connect to the 
controller.  The primary purpose of Alternate Boot is to provide the capability to boot the controller in 
case of hard disk failure, to perform system diagnostics, and load controller software, independent of 
other sub-systems. 
To enter this mode a user must strike any key on the PSW within 10 seconds of power on.  If the 10 
seconds times out, then the normal boot sequence occurs and the serial port acts as a typical tty (see 
next section).  However, if this mode is entered, a Xerox unique serial protocol is used to communicate to 
the alt-boot code.  All commands are DOS-type menu driven (i.e. type in a number to start a command). 
If a PSW is connected, the application on the PSW cannot be accessed without logging on with a 
password (see next section). 
If the PSW is used and is successfully logged on, then the Ethernet port is used to download executable 
files.  The serial port is used for commands and status.  Again, please refer to the PSW section for details. 
3.4.3. tty Mode 
When the controller has completed booting a login line will be displayed.  This mode is a typical tty 
window, and is password protected.  This password changes with each major software release.  The 
password is stored on the controller hard disk in an encrypted format similarly to how UNIX encrypts and 
stores passwords.  Through this port a user can gain information and access to any files or information 
stored in the controller DRAM or controller hard disk.  However, this mode is only used by a CSE if directed 
by a Field Engineer when all other diagnostics fail to solve a problem.  The written repair procedures that 
direct the CSE never employ this mode. 
3.4.4. Diagnostics via Portable Service Workstation (PSW) Port 
When connected to the PSW Port, the PSW provides an extensive suite of diagnostic functions for use by 
the Xerox Customer Service Engineer (CSE).  The over-the-wire protocol is Xerox proprietary.  This port 
cannot process any other protocol except this proprietary protocol used for machine diagnosis.  Also, the 
PSW must have an application loaded to connect to and communicate with the device.   
Customer documents or files cannot be accessed during a diagnostic session, nor are network servers 
accessible through this port.