Beeper Definitions
The scanner issues different beep sequences and patterns to indicate status. 
 defines beep sequences 
that occur during both normal scanning and while programming the scanner.
Table 2-1    
 Beeper Definitions
Beeper Sequence
Indication
Standard Use
Low/medium/high beeps
Power up.
Short high beeps
A bar code symbol was decoded (if decode beeper is 
enabled).
4 long low beeps
A transmission error was detected in a scanned symbol. The 
data is ignored. This occurs if a unit is not properly 
configured. Check option setting.
5 low beeps
Conversion or format error.
Low/high/low beeps
Advanced Data Formatting (ADF) transmit error. (For 
information about ADF programming, refer to the Advanced 
Data Formatting Programmer Guide, p/n 72-69680-xx.)
High/high/high/low beeps
RS-232 receive error.
Parameter Menu Scanning
Short high beeps
Correct entry scanned or correct menu sequence performed.
Low/high beeps
Input error, incorrect bar code or “Cancel” scanned, wrong 
entry, incorrect bar code programming sequence; remain in 
program mode.
High/low beeps
Keyboard parameter selected. Enter value using bar code 
keypad.
High/low/high/low beeps
Successful program exit with change in the parameter 
setting.
Low/high/low/high beeps
Out of host parameter storage space. Scan 
.
Code 39 Buffering
High/low beeps
New Code 39 data was entered into the buffer.
3 Beeps - long high beeps
Code 39 buffer is full.
Low/high/low beeps
The Code 39 buffer was erased or there was an attempt to 
clear or transmit an empty buffer.
Low/high beeps
A successful transmission of buffered data.