Chapter 3 Maintenance and Technical 
Specifications
Introduction
This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal 
descriptions (pinouts).
Maintenance
Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy.
Do not allow any abrasive material to touch the window.
Remove any dirt particles with a damp cloth.
Wipe the window using a tissue moistened with ammonia/water.
Do not spray water or other cleaning liquids directly onto the window.
Battery Maintenance
When batteries are stored over a year, battery cell manufacturers advise that some irreversible deterioration in 
overall battery quality may occur. To minimize this loss, they recommend storing batteries half charged in a dry, 
cool place between 41° and 77°F (5° and 25°C), the cooler the better, and removed from the equipment to prevent 
the loss of capacity. Batteries should be charged to half capacity at least once a year. In order to charge a battery 
to half capacity, take a fully discharged battery and charge it for 2 hours. If an electrolyte leakage is observed, avoid 
any contact with the affected area and properly dispose of the battery.